AOV140 /SRHP

AOV140 /SRHP

Combined Smoke and Access Hatches 

Modern Design with High Functionality

AOV 140 is a sleek, insulated, and CE-certified smoke and access hatch designed for installation on roofs. Made of aluminium and available in any RAL colour, it blends seamlessly with the building’s architecture—without compromising on safety or performance.

The hatch opens to a 140-degree angle and also functions as a comfort ventilation unit.

 

AOV 140 – Technical Specifications

– Material: Aluminium

– Insulation: 50 mm mineral wool

– U-value: 0.63 W/m²K

– Control: Electric motor (24V DC / 4A) according to EN 12101-2

– Opening angle: 140°

-Maximum roof pitch: 15°

– Standard upstand height: 300 mm

-CE marking: 1369-CPR-0088

– Environmental assessments: Approved in both Byggvarubedömningen and SundaHus

 

Available Sizes

– 900 × 900 mm (minimum)

– 1050 × 1050 mm (110 kg, 1.03 m²)

– 1260 × 1260 mm (132 kg, 1.52 m²)

– Maximum size: 1260 × 1260 mm

 

SRHE /AOV – Covered Smoke Hatch with Enhanced Insulation

SRHE / AOV is an electrically operated, CE-certified smoke ventilation hatch. It is suitable for properties requiring both functionality and architectural appeal.

 

Technical Specifications

– Material: Aluminium

– Insulation: 50 mm PIR

– U-value: 0.43 W/m²K

– Maximum roof pitch: 30°

– CE marking: 2822-UKCA.CPD-0075

– Standard: EN 12101-2:2003

 

Available Sizes

– 1050 × 1050 mm

– 1250 × 1250 mm

– 1500 × 1200 mm

– 2000 × 1200 mm

– 2500 × 1800 mm

– 3000 × 1800 mm (maximum)

 

Performance According to EN 12101-2

– WL (Wind Load): 1500 Pa

– SL (Snow Load): 500 Pa

– RE (Reliability): 1000 cycles

– Temperature Class: 300°C

 

Why Are Smoke Ventilation Hatches Important?

Smoke hatches play a critical role in fire safety within buildings. They:

– Efficiently extract smoke and hot gases during a fire

– Improve visibility in evacuation routes

– Reduce the risk of smoke inhalation

– Support the efforts of emergency services

– Protect the building’s structural integrity from overheating

They are particularly essential in residential buildings, stairwells, warehouses, and industrial premises.

 

How Are Smoke Hatches Activated?

– Automatically: via smoke detector or fire alarm system

– Manually: using a push button or emergency release

Note: Hatches in our product range are not activated by thermal fuses.

 

Regulations & Certification

Our smoke hatches comply with the requirements of:

– The Swedish National Board of Housing, Building and Planning (BBR)

– SS-EN 12101-2

– CE marking

– Byggvarubedömningen & SundaHus

They are approved for use in Sweden and are often mandatory for building permits in specific types of properties.

 

Product sheet & documents

We’ll help you find the right product!

Our advisors will guide you to the right hatch for your needs.